Описание

  • Guard locking with guard lock monitoring
  • Emergency stop according to ISO 13850, illuminated
  • 5 pushbuttons illuminated, 1 pushbutton not illuminated
  • Including adhesive labels
  • Connection via 7/8 and M12 plug
  • Including terminal plug for enabling switch (RC12, 12-pin)
  • Pre-assembled on mounting plates
  • Integrated Profinet RT switch
  • Unicode
Profinet connection 7/8 plugs according to ANSI/B93.55M-1981 and M12 plugs (d-coded) according to IEC 61076-2-101 Profinet RT switch Point-to-point topology network structure due to integrated RT switch. Flexible usage as interlocking or guard locking By means of the corresponding evaluation of the safe device data by the control system, usage can be either as interlocking or guard locking (with or without monitoring). Illuminated emergency stop Emergency stop with illumination that can be controlled as required. Dimension drawing Dimension drawing Technical dataApprovals Mechanical values and environment
Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
Weight
Net 3,1 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Degree of protection IP54
Resilience to vibration In accordance with EN 60947-5-3
Mechanical life 1 x 106
In case of use as door stop, and 1 Joule impact energy 0,1 x 106
Installation orientation Door hinge DIN left
Reaction time
Emergency stop / machine stop max.250 ms Switch-off time
Enabling switch max.250 ms Switch-off time
Door position max.550 ms Switch-off time
Bolt position max.550 ms Switch-off time
Guard locking max.550 ms Switch-off time
Switching frequency 0,25 Hz
Connection 7/8 Power
Acc. to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e M12 D-coded, screened
M12 D-coded, screened
7/8 Power
Guard locking principle Closed-circuit current principle
Locking force FZh 2000 N
Electrical connection ratings
Current consumption max.500 mA
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0,5 kV
Maximum feed-in current in the connection block
X1, X2 max.4000 mA
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
Degree of contamination (external, according to EN 60947-1) 3
Connecting cable
Ethernet Profinet I/O cable, at least cat. 5e
Safety class III
Transponder coding Unicode
Power supply X1
Operating voltage DC
L1 24 V DC -15% ... +10%
Auxiliary voltage DC
L2 24 V DC -15% ... +10%
Fusing
external min.1 A Slow blow
Power supply X2
Operating voltage DC
L1 24 V DC -15% ... +10%
Auxiliary voltage DC
L2 24 V DC -15% ... +10%
Work area
Assured switch-off distance Sar max.65 mm
Interface, bus
Data interface
Data protocol
Safety protocol Profisafe (IEC 61784-3-3)
Bus protocol Profinet (IEC 61158 type 10)
Controls and indicators
Belegungsschema B1
Belegungsschema L1
Position 1
Ausfuhrung Emergency stop illuminated
Einlegeschild
Extras
Farbe
Schaltelement 2 pos. driven NC
Position 90
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe Green
Schaltelement 1NO
Position 91
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe Blue
Schaltelement 1NO
Position 92
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe white
Schaltelement 1NO
Position 93
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe Yellow
Schaltelement 1NO
Position 94
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe white
Schaltelement 1NO
Position 95
Ausfuhrung Push buttons, not illuminated
Einlegeschild
Extras
Farbe Black
Schaltelement 1NO
Other
Product version number V3.30.10
Slide-in label
6 pc. without marking
AANVRAAG TOEGANG
RESET ALARM
START
MAINTENANCE
CYCLUS STOP
STOP
NIET IN GEBRUIK
REQUEST ACCESS
MAINTENANCE
CYCLE STOP / UNLOCK
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position
Category 4
Performance Level PL e
PFHD 4.07 x 10-8
Diagnostic Coverage (DC) 99
Control of the guard locking
Category 4
Performance Level PL e
PFHD 3.91 x 10-8
Emergency stop
B10D
Emergency stop 0.1 x 106
Emergency-stop evaluation
Category 4
Performance Level PL e
PFHD 4.1 x 10-8
Enabling switch
B10D
Enabling switch According to manufacturer’s specifications
Enabling switch evaluation
Category 4
Performance Level PL e
PFHD 4.1 x 10-8
Safety Integrity Level SIL 3 (EN 62061:2005)
Mission time 20
''