Описание

  • Guard locking with guard lock monitoring
  • Three illuminated pushbuttons
  • including adhesive labels
  • Push-pull plug
  • Including terminal plug for enabling switch (RC12, 12-pin)
  • Pre-assembled on mounting plates
  • Integrated Profinet RT switch
  • Multicode
Profinet connection Connection via push-pull plugs according to IEC 61076-3-117 Profinet RT switch Point-to-point topology network structure due to integrated RT switch. Flexible usage as interlocking or guard locking By means of the corresponding evaluation of the safe device data by the control system, usage can be either as interlocking or guard locking (with or without monitoring). Dimension drawing MGB: The MGB-System in use MGB: MGB Impact test MGB: Mounting left door, with escape release Mounting left door, without escape release Mounting right door, without escape release MGB: Deactivating guard lock monitor MGB: Activating guard lock monitor MGB: Activating release monitoring MGB: Change color-lens push button Dimension drawing Technical dataApprovals Mechanical values and environment
Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
Weight
Net 3,1 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Degree of protection IP54
Resilience to vibration In accordance with EN 60947-5-3
Mechanical life 1 x 106
In case of use as door stop, and 1 Joule impact energy 0,1 x 106
Installation orientation Door hinge DIN right
Reaction time
Enabling switch max.250 ms Switch-off time
Guard locking max.550 ms Switch-off time
Bolt position max.550 ms Switch-off time
Door position max.550 ms Switch-off time
Switching frequency 0,25 Hz
Connection Plug connector RC12
According to IEC 61076-3-117 variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45
Push-pull RJ45
Push-pull power
Push-pull power
Guard locking principle Open-circuit current principle
Locking force FZh 2000 N
Electrical connection ratings
Current consumption max.500 mA
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0,5 kV
Maximum feed-in current in the connection block
X1, X2 max.4000 mA
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
Degree of contamination (external, according to EN 60947-1) 3
Connecting cable
Ethernet Profinet I/O cable, at least cat. 5e
Safety class III
Transponder coding Multicode
Power supply X1
Operating voltage DC
L1 24 V DC -15% ... 10%
Auxiliary voltage DC
L2 24 V DC -15% ... +10%
Fusing
external min.1 A Slow blow
Power supply X2
Operating voltage DC
L1 24 V DC -15% ... 10%
Auxiliary voltage DC
L2 24 V DC -15% ... +10%
Work area
Assured switch-off distance Sar max.65 mm
Interface, bus
Data interface
Data protocol
Bus protocol Profinet (IEC 61158 type 10)
Safety protocol Profisafe (IEC 61784-3-3)
Controls and indicators
Belegungsschema B1
Belegungsschema L0
Position 90
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe Red
Schaltelement 1NO
Position 91
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe white
Schaltelement 1NO
Position 95
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe Blue
Schaltelement 1NO
Other
Product version number V3.30.10
Slide-in label
Storung Quittieren
Zutritt Anforderung
Automatic Start
Failure Reset
Access Request
Line Start
Line Stop
S-Zone Reset
Automatik Start
Reliability values according to EN ISO 13849-1
Enabling switch evaluation
Category 4
Performance Level PL e
PFHD 4.1 x 10-8
Monitoring of guard locking and the safety guard position
Category 4
Performance Level PL e
PFHD 4.07 x 10-8
Diagnostic Coverage (DC) 99
Enabling switch
B10D
Enabling switch According to manufacturer’s specifications
Safety Integrity Level SIL 3 (EN 62061:2005)
Mission time 20
''